Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Endocr Pract ; 28(7): 684-689, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35487459

RESUMO

INTRODUCTION: The accurate interpretation of the cosyntropin (adrenocorticotropic hormone [ACTH]) stimulation test requires method- and assay-specific cutoffs of the level of cortisol. Compared with a historical cutoff (18 µg/dL) for polyclonal antibody-based immunoassays, lower thresholds were proposed for the Roche Elecsys II assay, which uses a monoclonal antibody. However, cutoffs for other commonly adopted, monoclonal antibody-based cortisol assays were not yet available. Here, we established the thresholds for the level of cortisol specific to the Abbott Architect immunoassay by comparing the measurements of the level of cortisol using 3 immunoassays. METHODS: The ACTH stimulation test was performed in patients with suspected adrenal insufficiency (n = 50). The serum cortisol level was measured using the Abbott Architect, Roche Elecsys II, and Siemens Centaur assays. The results of the Abbott assay were also compared with those of liquid chromatography-tandem mass spectrometry. The receiver operating characteristic analysis was performed to derive new diagnostic thresholds for the Abbott assay using the polyclonal antibody-based Siemens assay as the reference method. RESULTS: The concentrations of cortisol measured using the Abbott assay were similar to those measured using liquid chromatography-tandem mass spectrometry and the Roche Elecsys II assay but significantly lower than those measured using the Siemens assay. The optimized threshold for cortisol using the Abbott assay was 14.6 µg/dL at 60 minutes after stimulation (sensitivity, 92%; specificity, 96%) and 13.2 µg/dL at 30 minutes after stimulation (sensitivity, 100%; specificity, 89%). CONCLUSION: We recommend a threshold of 14.6 µg/dL for the level of cortisol at 60 minutes after ACTH stimulation for the Abbott assay. In comparison with the historical threshold of 18 µg/dL, the application of the new cutoff may significantly decrease false-positive results due to ACTH stimulation testing. The use of assay-specific cutoffs will be essential for reducing misclassification and overtreatment in patients with suspected adrenal insufficiency.


Assuntos
Insuficiência Adrenal , Cosintropina , Insuficiência Adrenal/diagnóstico , Hormônio Adrenocorticotrópico , Anticorpos Monoclonais , Humanos , Hidrocortisona , Imunoensaio/métodos
2.
J Immunol Methods ; 503: 113243, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35181288

RESUMO

INTRODUCTION: Serological testing is an important tool to assist with assessing the immune response to SARS-CoV-2 infections, the causative agent of COVID-19. A quantitative assay was recently developed by Abbott Laboratories to measures antibodies against the receptor binding domain of the spike protein. In addition to assessing disease prevalence, this assay is useful towards determining the scale and duration of the humoral response to infection and vaccination. Here we evaluated the clinical and analytical performance of the quantitative Abbott AdviseDx SARS-CoV-2 IgG II assay and characterized the longitudinal dynamics of the IgG response against SARS-CoV-2 in 402 infected individuals up to 322 days post-symptom onset. METHODS: To assess test sensitivity, 1257 serum specimens derived from 402 patients positive for SARS-CoV-2 by RT-PCR were analyzed on the Abbott Alinity platform. To evaluate test specificity, 394 specimens were tested from patients who were symptomatic but PCR negative for SARS-CoV-2, as well as 305 archived pre-pandemic samples. To further characterize test performance metrics, we evaluated assay precision and linearity. RESULTS: The Abbott AdviseDx SARS-CoV-2 IgG II assay exhibited diagnostic specificity of 99.02% using 305 pre - COVID-19 serum specimens and 98.73% using 394 PCR negative specimens. Using 1257 sequential serum samples collected from PCR-confirmed individuals, clinical test sensitivity of the assay was 39.7% at 3-7 days, 75.9% at 8-14 days, 95.6% at 15-21 days, and 98.7% at 4-5 weeks post-symptom onset. The assay is linear across the analytical measurement range claimed by the manufacturer (22-25,000 AU/mL) and exhibited good analytical precision. The median concentration of IgG increased steadily from <22 AU/mL at 3-7 days post-symptom onset, to a peak of 14,421 AU/mL at 6-7 weeks. Although antibody concentration started to decline at 8-9 weeks following symptom onset, all patients remained seropositive during the observation period. When the positivity rate of this assay was compared with the Abbott anti-NP IgG and EUROIMMUN anti-S1 IgG tests, clinical sensitivity of the Abbott AdviseDx SARS-CoV-2 IgG II assay was the highest at all time points with the exception of 4-5 weeks after symptom onset. CONCLUSION: The Abbott AdviseDx SARS-CoV-2 IgG II assay offers high test specificity and sensitivity across a broad reportable range. We anticipate this assay will be a useful towards quantitatively assessing the humoral immune response to COVID-19 infection and vaccination.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Humanos , Imunoglobulina G , Sensibilidade e Especificidade , Testes Sorológicos
3.
J Clin Virol ; 133: 104663, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33161369

RESUMO

BACKGROUND: Antibody testing has recently emerged as an option to assist with determining exposure to SARS-CoV-2, the causative agent of COVID-19. Elucidation of the kinetics and duration of the humoral response is important for clinical management and interpreting results from serological surveys. OBJECTIVES: Here we evaluated the clinical performance of Abbott SARS-CoV-2 IgM and IgG assays, as well as the longitudinal dynamics of the antibody response in symptomatic COVID-19 patients. STUDY DESIGN AND RESULTS: The diagnostic specificity was 100 % for IgM and 99.67 % for IgG using 300 pre-COVID-19 serum specimens. Using 1349 sequential serum samples collected up to 168 days post symptom onset from 427 PCR-confirmed individuals, clinical test sensitivity of the SARS-CoV-2 IgM assay was 24.6 % at ≤7 days, 75.3 % at 8-14 days, 95.0 % at 15-21 days, and 96.0 % at 4-5 weeks (peak test sensitivity). The median duration of time for IgM seroconversion was 10 days. IgM levels declined steadily 4-5 weeks after symptom onset, and the positive rate dropped to 30.8 % at >3 months. The diagnostic sensitivity for the SARS-CoV-2 IgG assay post symptom onset was 23.2 % at ≤7 days, 69.5 % at 8-14 days, 93.6 % at 15-21 days, and 99.6 % at 4-5 weeks (peak test sensitivity). The median duration of time for IgG seroconversion was 11.5 days. During the convalescent phase of the infection, a decline in the IgG level was observed in patients who were followed for >100 days. Despite that decline, 92.3 % of the patient cohort remained IgG positive 3-6 months following symptom onset. CONCLUSIONS: This study demonstrates the Abbott IgM assay against SARS-CoV-2 is detected slightly earlier compared to IgG, with both tests exhibiting excellent overall sensitivity and specificity. In symptomatic patients who test negative by PCR for a SARS-CoV-2 infection, assessing IgM and IgG antibodies can aid in supporting a diagnosis of COVID-19.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19 , COVID-19/diagnóstico , Imunidade Humoral , Imunoglobulina G/sangue , Imunoglobulina M/sangue , COVID-19/imunologia , Estudos de Coortes , Humanos , Estudos Longitudinais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Inorg Chem ; 46(18): 7362-70, 2007 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-17691722

RESUMO

Hydrothermal synthesis has afforded a family of divalent metal adipate (adp) coordination polymers incorporating the kinked dipodal organodiimine 4,4'-dipyridylamine (dpa). As revealed by single-crystal X-ray diffraction, the structures of these materials are critically dependent on the metal coordination geometry, the carboxylate binding modes, and the conformations of the flexible adipate moieties. In all cases, hydrogen-bonding interactions imparted by the dpa tethers also play a structure-directing role. All materials were further characterized via infrared spectroscopy and elemental and thermogravimetric analysis. [Co(adp)(dpa)] (1) displays doubly interpenetrated three-dimensional (3-D) networks with a decorated alpha-Po-type (pcu) topology. In contrast, [Ni(adp)(dpa)(H2O)] (2) possesses a triply interpenetrated binodal cooperite-type (pts) framework, the highest level of interpenetration yet reported for this structure type. [Zn(adp)(dpa)].H2O (3) presents mutually inclined polycatenated 2-D graphitic layers consisting of neutral dimeric [Zn2(mu2-adp)2] kernels conjoined by dipodal dpa ligands. Compound 1 exhibited weak antiferromagnetic coupling between its carboxylate-bridged Co atoms, following Curie-Weiss behavior with Theta=-3.3 K. Compound 3 manifested blue light emission under ultraviolet excitation, as well as a reversible structural reorganization upon dehydration/rehydration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...